Item Tag: ≤1350W

July 14, 2026 Comments (0)

Lab Microwave Reactor Continuous Chemical Radiation Oven 2450MHz±50Hz 250℃ 110V

The characteristics of microwave heating: 1. Fast response ability: can quickly start, stop and adjust the output power. 2. Uniform heating: both inside and outside heating. 3. Selective heating: high dielectric loss, high temperature after heating, and vice versa. 4. High heating efficiency: due to the heating of the heated object itself, there is no heat conduction process, so there is no heat loss around the air and the heated cavity. 5. High heat penetration: heat penetration and wavelength is of the same magnitude up to ten centimeters, and infra-red heating for heating surface, the penetration depth is only several micrometers.Lab Microwave Reactor Continuous Chemical Radiation Oven 2450MHz±50Hz 250℃ 110V Product Features Fast heating: microwave can propagate in the body at the speed of light (3×1010cm/s). Instantly, in less than 10-9 seconds, microwave energy can be converted to the heat energy of matter, and the heat energy can be penetrated into the heated material without heat conduction. Fast response ability: can quickly start, stop and adjust the output power. Uniform heating: both inside and outside heating. Selective heating: high dielectric loss, high temperature after heating, and vice versa. High heating efficiency: due to the heating of the heated object itself, there is no heat conduction process, so there is no heat loss around the air and the heated cavity. High heat penetration: heat penetration and wavelength is of the same magnitude up to ten centimeters, and infra-red heating for heating surface, the penetration depth is only several micrometers.Description of Product The MCR-3SX-T microwave chemical reactor adopts the latest technology to ensure the smooth operation of the experiment.Continuous microwave output: Research shows that pulsed microwaves produce high threshold electromagnetic pulses at the moment of “on” and “off”, resulting in large temperature oscillations and easily destroying the organic molecule form, thus affecting the consistency of the experimental results. The continuous microwave output ensures the presence of microwaves at all times during the experiment, overcoming the adverse effects of pulsed microwaves on the experiment. Microcomputer adaptive PID adjustment technology: effectively overcome the occurrence of overshoot phenomenon, flexible to adapt to different operating environments, when the environmental temperature, reaction substance volume, polarity, heat capacity change, FCMCR-3SX-T microwave chemical reactor can adapt to the resulting impact, automatic frequency adjustment of output power, so that the instrument to adapt to the new environment, to maintain temperature control accuracy does not decrease. Teflon-coated Pt100 platinum resistance temperature sensor: The temperature sensor is directly inserted into the reaction system to collect the temperature of the reaction material, and the reliable shielding device effectively eliminates the self-heating effect and the interference of electromagnetic waves, making the data collection more reliable. Teflon can effectively resist acid, alkali and organic solution corrosion. Adopt multi-stage working mode: 30 working periods can be set. After one working period, the microwave chemical reactor automatically shifts to the next period of continuous work. The maximum power, temperature and time can be set independently under each period, and the FCMCR-3SX-T microwave reactor will reach the optimal condition in each working period. With computer on-line monitoring function: The instrument is equipped with RS485 communication interface, which can communicate with the computer side in real time to realize various functions such as monitoring, setting, controlling and recording, recording valuable experimental data for you. Temperature error correction function, if there is an error between the displayed temperature and the actual temperature, it can be corrected by modifying the internal parameters of the microcomputer. With safety chain switch: in any case open the door will stop microwave radiation to protect the safety of users. Magnetron overheating protection function: When the magnetron temperature is high due to a long time of use or abnormal conditions, the microwave chemical reactor can automatically cut off the magnetron power supply to avoid damage to the magnetron. Built-in magnetic stirrer, the stirring speed is steplessly adjustable. Open reaction system: users can add standard mouth reaction vessel (volume 100-500ml) and condensation reflux, drop addition, liquid replenishment and other devices according to the reaction conditions required by the process. Equipped with protective gas adding port. The microwave chemical reactor has the function of exhausting air and smoke. Packing listMicrowave chemical reactor 1Power line 1An instruction manual 1Insurance pipe 2250ml boiling flask-2-neck 1250ml boiling flask-3-neck 1Glass tube 1Glass two fork tube 1Y-pipe 1Gas protective cork 1Glass cork 1Teflon cork 1Teflon agitator 2Please pay attention to the following points:1.Microwave reactors are prohibited from opening microwave output without any load. Otherwise, it will cause an irreversible failure of the microwave generator. The load must be a polar substance, and the non polar substance will not consume energy in the microwave condition, which will also cause the damage of the microwave generator. In the case of conditions allowed, the semi beaker glycerol can be placed in the cavity for a long time to prevent dry burning. 2. Temperature control precision: The instrument used water and glycerin to test the temperature before leaving the factory, so that the temperature control accuracy was within the range of ±1℃. In order to ensure the accuracy of temperature control, the temperature should be self – adjusted by the experimental solvent before the experiment is carried out. Press ◄ key for three seconds, PV window display AT,SV window display OFF. Press ▲ key to chose ON,then press SET key to confirm. After the beginning of the self-tune, the SV window AT flashes, and the temperature value can be displayed at the end of the self-tune, and it can be used normally. 3. At the end of each experiment, we must close the microwave output according to STOP and turn off the machine. Otherwise, the microwave output will be automatically opened at the next start of the machine. The correct operation steps are: open the door, put the flask, connect the pipeline, open the switch, set the reaction temperature, run (RUN), stop at the end (STOP), remove the reactant, close the door and close the switch.PaymentDelivery detailsTerms of salesAbout usContact usPaymentPayment should be completed within 4 (Four) days of auction closing. Or unpaid dispute will be filed for closing auction.We will leave a positive feedback immediately after payment is received. We appreciate a positive feedback as much as you do. If for some reason there is any issue with the purchase, please contact us prior to leaving feedback, we will be glad to work together and provide a satisfying solution.Delivery detailsWe only ship the item to the eBay Verified address that is sent to us at the time of checkout, most shipment will be shipped within 1-5 business day. Please verify the correct shipping address in your eBay account before making your payment. Shipping time during holidays may take longer than normal. Any brokerage, customs, and duty fees associated with international shipments are the customer’s responsibility and are not included in our shipping charges. If you are located outside of the continental 48 United States, please email us in advance to see if the specific item ships to your location. These orders are generally shipped within 1-5 days after payment is received. Please be patient as they are often subject to additional inspection upon delivery.Terms of salesAll of our items are backed with a 30-day return policy. We ensure all our items are new and in excellent condition prior to shipping. In case you receive the item that is not to the standards above, please contact us via e-Bay messages. All returns must be in new original condition as received and should be shipped with delivery confirmationPlease note that all returns must be pre-approved by us. Unauthorized returns will not be accepted. If you need to return, please check twice to confirm the item not work and contact our customer service representative, let us know the detailed problem and send us some pictures for confirmation.We ONLY accept returns with original package. Please make sure that item has NO man-made sabotage. Used items will not be accepted for return.About usWe are a comprehensive company specializing in the research and development, production and sales of lab related equipment. Company tenet: Respect reputation and contract, provide high-quality and low-cost equipment for serve scientific research.We believe that it is our vision and mission to provide innovative products with best service and competitive price to satisfy you. Our goal is to make sure that you can find exactly what you are looking for and make it easy for you to place your orders.Contact usEmail Customer Support:9:00am-2:00am PST Sunday-FridayAll emails will be responded to within 12-24 hoursBrandMTSTMPN0796753403235Reactor TypeMicrowave ReactorModelMCR-3RTIntended Use/DisciplinePhysical LaboratoryCountry/Region of ManufactureChinaMaterialStainless SteelHuman Interface InputButtonsInstallation TypeDetachedMicrowave Frequency2450MHz±50HzWeight110 PoundsInput power≤1350WMicrowave output modeContinuous waveOutput power≤900WTemperature control precision≤1℃Accuracy of measurement value0.2Temperature setting range0.0~250.0℃Power supply voltageAC 110V 60HZ (220V 50HZ optional)Ambient temperature0~50℃Relative humidity<85%RHOverall dimension510×450×510 mmInternal bile size352×325×202 mmCommunication portRS485 communication output

Explore More

Can’t afford delays?

Your equipment saves lives. Partner with us — we deliver safely, on time, every time.

Timing: 11:00 AM to 11:59 PM

About Glavik

We work with passion, embracing challenges and creating new opportunities across healthcare logistics, dangerous goods, and beyond.

Office # 240, 2nd floor, Landmark Plaza, Jail Road, Lahore, Punjab, Pakistan.

Copyrights © 2026 GLAVIK. All Rights Reserved.

Developed by Anifar Technologies