Item Tag: iE300

July 7, 2026 Comments (0)

Biocare 12 lead ECG Machine Portable with Au-to Analysis Diagnosis ECG, Printer

Biocare iE300 12-Lead ECG Machine12-Lead ECG MachineProfessional, Accurate, PortablePortable 12-lead ECG with automatic analysis. Professional choice for hospitals and clinics.NOTE: This device can not work with a pacemaker!!! Free Delivery1 Year Official WarrantyFree ReturnsMoney Back GuaranteeAward Winning Customer Service Feature: 12-Lead EKG, Simultaneous Acquisition View everything about heart in one machine.View the essentials of a patient’s heart in one small machine, including waveforms and heart rates in realtime. 5 data formats in ECG, XML, JPEG, DICOM, and PDF. We support 15 languages for operation, voice reminder and visual alarming for lead-off, low battery and out of printing paper. Portable enough to carry it room to room. This portable ECG machine only weighs 1.3kg (2.9lbs). Compares to many EKG devices which normally weighs about 2kg (4.4lbs), iE 300 is definitely a great choice for medical professionals to use on a daily basis. Take it to where patients need the most. The set also includes a metal handle for doctors and physicians to carry it around between different patient rooms. You can also put the device at the patient’s bedside for an efficient medical treatment process. Auto-analysis of Different Heart Diseases The EKG machine can analyze the resting ECG and output the measurement data, median beat, and analysis result. After waveforms collecting, iE 300 12-lead ECG will automatically analyze the waveforms and enter to the report interface.Up to 300 seconds of rhythm analysis makes arrhythmia locating much more easier. Advanced Features Make Expert Operation Easier 5.0 inch high resolution LCD full-view display, make every wave clearer.2 ways of charging: AC powered for unstoppable working mode; Built-in rechargeable battery to assure continuous operation when AC power is unavailable, up to 3-hours.2 peripheral ports: USB port for saving data on USB devices and LAN for net connection.1500 files of massive storing space. View and Print in 3 Report FormatsSimple Report includes patient information, simple measurement data and Minnesota code. Median Beat Report includes patient information, simple measurement data, Minnesota code, median beat waveform and rhythm waveforms. In Manual Mode, the reports include analysis report (1), and report (2). You can switch from one column to another by pressing at any time to control the waveform length of every leads. In the above two interfaces, you can select to upload, save, and print the report. In the analysis report (1), the analysis result can be manually edited by the user. Please refer to the List of Interpretation Codes and Corresponding Description in the User Guide for the details of the analysis result. Report (2) includes waveforms of all the leads. Waveform Review of 300 Seconds During the Rhythm mode, the system will begin HRV acquisition (the fixed acquisition time is 300s). After this process ends, feel free to save, print and upload the report. You can also review the waveform during this 300 seconds. 3 channels, know patient’s condition directly. The writer prints the analysis in 3×4 format.So you can get a quick view of your patients in just a few seconds. Adjustable printing speed from 5mm/s to 50mm/s. Choose the data format you want in ECG, DICOM, XML, JPEG and PNG. Specification:WEIGHT (MAIN UNIT):2.9lbs / 1.3kgDEVICE DIMENSIONS:11.1” x 7.5” x 2.3” (281mm x 191mm x 59mm)SCREEN:5.0” TFT LCD full-view displayAC POWER SUPPLY :100V-240V, 50Hz/60Hz, 80VA DC POWER SUPPLY:Rechargeable built-in lithium battery (11.1V/2600mAh), support 3-hour operationLEAD :12 leadsACQUISITION MODE:Simultaneous 12-lead AcquisitionRHYTHM TIME:30s~300s waveforms acquisition for rhythm analysis COMPATIBLE COMPUTER SYSTEM:Windows XP, Win7, Win8, Vista in 32/64 bitPRODUCT:Digital Electrocardiograph (Model: iE300)RECORD FORMAT:1 x 12, 1 x 12 + 1R, 3 x 4, 3 x 4 + 1R, 3/2 RECORDER:Thermal Dot Matrix Word Printing SystemRECORDING PAPER:80mm x 20mtr, rolled paper PRINTING SPEED:(5, 6.25, 10, 12.5, 25, 50) mm/s ±5% MEMORY SPACE:1500 records Package include:Main ECG UnitLead Wires (1 set)Limb Electrodes (1 set)Chest Electrodes (1 set)ECG Snap-Clip Adapters (10 pieces)Disaposable Electrodes (10 pieces)Power CableEquipotential CableThermal Recording Grid Paper (1 roll)Paper RollerHandle Set (1 set)User ManualQualified CertificatePacking List

Explore More
July 7, 2026 Comments (0)

Biocare iE6 12 lead 6 channel ECG Machine Touchscreen with interpretation FDA US

About the item【1】12-lead synchronized acquisition, 6-channel synchronized/real-time printing.【2】8-inch LCD display, designed with PC keyboard and shortcut function keys.【3】Next-generation acquisition system, quickly stable waveforms, saving examination time.【4】Frequency response of 0.05-250Hz, high-precision recording, more suitable for capturing pediatric electrocardiographic waveforms.【5】Supports various data formats such as XML, JPG, DICOM, facilitating network sharing.【6】Internal storage for 21,500 medical records, and supports external storage such as large-capacity SD cards and USB drives.Tech SpecsPRODUCT:Digital Electrocardiograph (Model: iE6)WEIGHT (MAIN UNIT):5.5lbs / 2.5kgDEVICE DIMENSIONS:10.1” x 11.4” x 4.2” (257 mm×291 mm×106 mm)SCREEN:8.0” TFT LCD full-view displayAC POWER SUPPLY:100V-240V, 50Hz/60Hz, 80VA DC POWER SUPPLY:Rechargeable Lithium battery(14.8V/ 2200mAh)for 3-hour continuous operationLEAD MODE:Standard 12 leads, CabreraPATIENT TYPE:Adults (older than 12 years old); Pediatrics (age: 29 days – 12 years old); neonates (infants born less than 28 days)ACQUISITION MODE:Simultaneous 12-lead AcquisitionRHYTHM TIME:30s~300s waveforms acquisition for rhythm analysis COMPATIBLE COMPUTER SYSTEM:Windows XP, Win7, Win8, Vista in 32/64 bitSAMPLING RATE:8,000 samples/second/channelRECORD FORMAT:12-lead: 3×4,3×4+1R,3×4+3R,6×2,6×2+1R,1×12+1R;Nehb-lead: 6×1,3×2RECORDER:Thermal Dot Matrix Word Printing SystemRECORDING PAPER:Z- fold paper, 112 mm×140 mmPRINTING SPEED:(5, 6.25, 10, 12.5, 25, 50) mm/s ±5% DATA STORAGE:≥3500 records (10-second acquisition)USB Port:USB 2.0 driveCERTIFICATION:NMPA, FDA, CEPacking ListMain ECG UnitPatient Lead Wire (1 set)Limb Clamp Clip (1 set)Chest Suction Ball (1 set)ECG Snap-Clip Adapters (10 pieces)Disaposable Electrodes (10 pieces)Power Cables (US & EU Standard)AC Power AdaptorEquipotential Grounding CableThermal Recording Grid Paper (z-fold paper)User ManualQualified Certificate

Explore More
July 6, 2026 Comments (0)

Biocare iE300 12 lead ECG Machine rapid diagnosis and instant ECG tests FDA US

Biocare iE300 12 lead ECG Machine rapid diagnosis and instant ECG tests FDA US ITEM UNTESTED (UNABLE TO TEST), ITEM HAS SCUFFS / SCRATCHES, INCLUDES EVERYTHING WITHIN THE PHOTOS, NO ACCESORIES. SEE PHOTOS IF YOU HAVE ANY QUESTIONS PLEASE MESSAGE BEFORE PURCHASING THANK YOU PRODUCT DISCLAIMER & PARTS / REPAIR. We do not load software nor transfer ownership of items. We do not reset passwords. Items sold for Parts / Repair are given a general inspection power on testing(UNLESS SPECIFIED ITEM UNTESTED) and basic description. Keep in mind Parts / Repair items are sold as / is no warranty or guarantee and may have additional issues beyond the item description. Keep in mind we are not the original owners of these items so we have limited knowledge of functionality. Section 758.6 of the Export Administration Regulations (EAR) discusses when an exporter must incorporate a Destination Control Statement on certain export documents. The EAR provides the following statement to exporters: “These items are controlled by the U.S. Government and authorized for export only to the country of ultimate destination for use by the ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulations.”

Explore More

Can’t afford delays?

Your equipment saves lives. Partner with us — we deliver safely, on time, every time.

Timing: 11:00 AM to 11:59 PM

About Glavik

We work with passion, embracing challenges and creating new opportunities across healthcare logistics, dangerous goods, and beyond.

Office # 240, 2nd floor, Landmark Plaza, Jail Road, Lahore, Punjab, Pakistan.

Copyrights © 2026 GLAVIK. All Rights Reserved.

Developed by Anifar Technologies