1pc OOA101 Original ENVITEC Oxygen Sensor Oxiplus A for Medical Ventilator

  • Home  
  • 1pc OOA101 Original ENVITEC Oxygen Sensor Oxiplus A for Medical Ventilator
1pc OOA101 Original ENVITEC Oxygen Sensor Oxiplus A for Medical Ventilator

1pc OOA101 Original ENVITEC Oxygen Sensor Oxiplus A for Medical Ventilator

USD 55.60 USD
SKU: VEmw5ZFp
Condition: New

Specifications

Return Shipping Will Be Paid ByBuyer
All Returns AcceptedReturns Accepted
Item Must Be Returned Within30 Days
Refund Will Be Given AsMoney Back
ModelOOM101
Country/Region Of ManufactureGermany
Sensor/Probe TypeOxygen Sensor
MPNDoes Not Apply
BrandEnviteC
Intended Use/DisciplineAnesthesiology

Oxygen Sensor OOA101 Technical SpecificationsMeasurement range: 0 % ... 100 % oxygen (at atmospheric pressure)Nominal sensor lifetime: ≥ 1 000 000 % volume oxygen hoursOutput in ambient air: 13 mV ... 16 mVElectrical interface: 3 pin (Molex® 22-11-1031)Accuracy meets: ISO 80601-2-55 requirementsRepeatability: < 1 % volume O2 at constant temperature and pressureLinearity error: < 3 % relativeResponse time: < 12 s to 90 % of final valueZero offset voltage: < 200 µV in 100 % nitrogen, applied for 5 minCross interference meets: ISO 80601-2-55 requirementsInfluence of humidity: % rel. per % RH at 25 °CPressure range: 0.6 bar ... 2 bar (ppO2 0 ... 1250 mbar O2)Influence of pressure: proportional to change in oxygen partial pressureInfluence of mechanical shock: < 1 % relative after a fall from 1 mOperating temperature: 0 °C ... +50 °CTemperature compensation built-in NTC compensationEffect of temperature compensation (steady state): between +25 °C and +40 °C: 3 % relative error; between 0 °C and +50 °C: 8 % relative errorOperating humidity: 0 % ... 99 % RH non-condensingLong term output drift: < 1 % volume oxygen per monthtypically: < -15 % relative over lifetimeStorage temperature: -20 °C ... +50 °CRecommended storage: +5 °C … +15 °CRecommended load: ≥ 10 kOhmsWarm-up time: < 30 minutes, after replacement of sensorWeight approximately: 28 gramsPart number: 01-00-0047 Compatible with the following models:Analytical Industries PSR-11-917-MBird Products (VIASYS) Avea. VentCatalyst Research MSA 472062, 470644Ceramatec CAG-12City Technology MOX-9, MOX-09EME, Infant FlowHamilton Galileo, Raphael, Alladin HM-12, 51214Hudson 5566Infrasonics Adult Star 601T, 60116IT-Gambert M-04, M-16Maxtec MAX-12, MAX-16Mercury Medical 10-103-06Ohmeda O2 cell 6051-0000-222Pacifitech PT-12Puritan Bennett (PB Tyco) Ventilators 840, 740, 760 4-072214-00PPG Biomedical Saracap 504055-001Sensidyne SV-12ASensor Tec (BPR Medical) ST-12, ST-04Siemens Servo Ventilators, 900, 900C, 900D, 700, 710, 300, V710300, 9004979, 6419332Space Labs 90514, Gas Analyzer 015-0132-03Taema YR049700, Cesar 2, HorusTeledyne R24, R24MED, Cheiron R-24, Hill-ROM R-24Vascular Technology 103100Ventrex V-12AVTI 103100Nuova E-17/M Package 1pc

Related Items

Can’t afford delays?

Your equipment saves lives. Partner with us — we deliver safely, on time, every time.

Timing: 11:00 AM to 11:59 PM

About Glavik

We work with passion, embracing challenges and creating new opportunities across healthcare logistics, dangerous goods, and beyond.

Office # 240, 2nd floor, Landmark Plaza, Jail Road, Lahore, Punjab, Pakistan.

Copyrights © 2026 GLAVIK. All Rights Reserved.

Developed by Anifar Technologies